ORIGINAL ARTICLES
Year : 2021  |  Volume : 1  |  Issue : 1  |  Page : 12-18

Comparison of setup variations and defining a CTV-PTV margin in fractionated radiotherapy of brain tumor using Novalis Tx Orthogonal OBI (kv) versus Brain Lab ExacTrac (kv) imaging systems with brain lab mask


1 Department of Radiation Oncology, Indraprastha Apollo Hospital, New Delhi, India
2 Department of Medical Physicist, Indraprastha Apollo Hospital, New Delhi, India
3 Shobhit Institute of Engineering and Technology (Deemed to be University), Meerut, Uttar Pradesh, India

Correspondence Address:
Dr. Hemant K Pandey
Department of Radiation Oncology, Indraprastha Apollo Hospital, 668, Pocket A, Sarita Vihar, New Delhi 110076.
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/bjoc.bjoc_20_21

Rights and Permissions

The objective of this study is to evaluate the setup discrepancy between Brain Lab ExacTrac (kv) and Orthogonal Novalis Tx (kv) imaging systems and to obtain an optimal CTV-PTV margin. We recruited 35 consecutive brain tumor patients, immobilized with non-invasive thermoplastic BrainLab mask, between August 2016 and August 2017. The position verification done by ExacTrac, Infrared Positioning System was followed by a set of images by OBI at 0° and 90° position. The images were autofused and compared with DRR generated by TPS. The extent of translational and rotational shift was then applied and documented. The translational inter-fractional setup error (mean ± SD) in X-axis detected by OBI and ET was 0.002 ± 0.227 and −0.042 ± 0.084, respectively. In Y-axis, the error detected was −0.01 ± 0.176 and 0.075 ± 0.079, respectively, whereas in Z-axis the error with OBI and ET was 0.329 ± 0.521 and 0.051 ± 0.091, respectively. The P-value of inter-fractional errors in X, Y, and Z axes was 0.294, 0.013, and 0.004, which is statistically significant in Y- and Z-axes. Rotational inter-fractional setup errors (mean ± SD) for OBI and ET were −0.101 ± 0.257 and −0.076 ± 0.102, respectively. The rotational setup errors detected by ET in pitch and roll dimension are −0.003 ± 0.084 and −0.085 ± 0.073, respectively. The data obtained were put in Van Herk’s formula (PTV margin = 2.5 ∑ + 0.74 σ), and CTV-PTV margin was calculated. CTV-PTV margin for ET was 2.70, 2.72, and 2.94 mm and 3.38o, 2.84o, and 2.51o in lateral, longitudinal, vertical and pitch, roll, yaw dimension, respectively. The CTV-PTV margin for OBI was 7.40, 6.20, and 5.30 mm and 7.27o in lateral, longitudinal, vertical, and yaw dimension, respectively. Daily setup verifications that use the Brain LAB Exac Trac 6D image-guided system are very useful for brain tumor treatment; nevertheless, OBI kv imaging can be used for FRT of brain tumor with extended margin.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2299    
    Printed230    
    Emailed0    
    PDF Downloaded166    
    Comments [Add]    

Recommend this journal